Cables

We have cables for every industry. Automotive, marine, building, explosive, power flexes, welding flexes, garden lighting, multicore, pool and solar cable, instrumentation cable. High voltage, high temperature, high tension cables, measurement cables, pyrometric cables, motor lead, silicone insulated cables, multi-conductor cables, safety cables. Where it is important our we have cables that have UL, IEC, CSA, DIN and Veritas approval.

Applications

  • Cables
  • RECS (SIE VDE)
  • ECS (SIF VDE)
  • MC-ECS
  • ECSP
  • Silicoul 1.1 kV
  • Silicoul 3.7 kV
  • Silicoul 6.6 kV
  • Silicoul 13.8 kV
  • Varpren F
  • Varpren MVA
  • NVS and NVSL
  • BM-NVS
  • NVAS
  • TPT
  • HT
  • EETFE
  • EPFA
  • Thermocouple cables (COUPLIX)
  • RTD Cables (SONDIX)
  • Cables

    GENERAL
    OBA supplies a wide range of specialized cables, not only for the electric motor industry, but also for other applications.
    Our primary ranges are silicone, single core cables that are suitable for temperature ranges of -60°C to 180°C and -90°C to 450°C. This cable, suitable from -90°C to 450°C, is available in both single and multi-core types. Although the majority of these cables have copper conductors some are a nickel alloy for special applications.

    Also available are specialized cables that are suitable for temperatures up to 1400°C.

    In addition to the specialized range above cables for use in the following ranges of applications are available. For full detailed specifications please contact your nearest OBA office.

  • Low Voltage (Garden & Irrigation)
  • Data
  • Automotive
  • Marine
  • SELECTION
    Click here to view the Quick Find chart providing key information on the most common cables available from OBA, however if what you want is not on the list please ring your nearest OBA office.

    Download:
  • Data Sheet
  • RECS (SIE VDE)

    GENERAL
    Continuous working temperatures:

  • - 60°C to + 180°C, Peaks at + 230°C
  • Good resistance to thermal shock and UV
  • Excellent ageing resistance
  • Halogen free cable
  • Working voltage: cross-section <10 mm² 450/750 V cross-section >10 mm² 600/1000 V
  • Test voltage: 2000 V

    COLOUR
  • 0.25 to 6 mm2: all colours, including two-colour
  • 10 to 95 mm2: white, black, other colours on request

    PACKAGING
  • 100m Rolls, spools, drums or SILIBOX®

    OPTIONS
    Please consult OBA about these options.
  • Mechanical outer shielding:
  • in galvanized steel
  • in stainless steel

    APPLICATIONS
  • Wiring of domestic electrical heating appliances
  • Rotating machines (class H)
  • Lighting
  • Industrial wiring for hot environments

    CORE INSULATED WIRE OR CABLE
    Nominal cross-section    Nominal stranding   Max. linear resistance at 20 °C  (red copper wire)   Nominal thickness of
    Insulating sheath
    Nominal
    outer diameter
    Approx.
    linear weight
    [mm²] [Ω/km] [mm] [mm] [kg/km]
    0.25 1 x 0.56  74.5 0.6 1.7 5.30
    0.5 1 x 0.80  36.0 0.6 2.0 7.70
    0.75 1 x 0.98  24.5 0.6 2.2 10.7
    1 1 x 1.13  18.1 0.6 2.4 12.8
    1.5 1 x 1.38  12.1 0.6 2.6 18.0
    2.5 1 x 1.78  7.41 0.7 3.2 28.9
    4 1 x 2.26  4.61 0.8 3.9 45.4
    6 1 x 2.76  3.08 0.8 4.4 64.5
    10 7 x 1.38  1.83 1.1 6.4 121
    16 7 x 1.70  1.15 1.2 7.5 183
    25 7 x 2.14  0.727 1.6 9.6 285
    35 7 x 2.52  0.524 1.8 11.2 390
    50 19 x 1.78  0.387 2.2 13.3 550
    70 19 x 2.14  0.268 2.4 15.5 740
    95 19 x 2.52  0.193 2.6 17.8 1000


    Download:
  • Data Sheet
  • ECS (SIF - VDE)

    GENERAL
  • Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
  • Good resistance to thermal shock and UV
  • Excellent ageing resistance
  • Halogen free cable
  • Working voltage:
  • cross-section <10 mm² 450/750 V
  • cross-section >10 mm² 600/1000 V
  • Test voltage: 2000 V

    COLOUR
  • 0.25 to 6 mm²: all colours, including two-colour
  • 10 to 400 mm²: white, black, other colours on request

    PACKAGING
  • Rolls, spools, drums or SILIBOX®

    OPTIONS
  • Please consult OBA about these options.
  • Nickel-plated copper core
  • Pure nickel core
  • Mechanical outer shielding:
  • in galvanized steel
  • in stainless steel


  • APPLICATIONS
  • Wiring of domestic electrical heating appliances
  • Rotating machines (class H)
  • Urban lighting
  • Industrial wiring in hot environments
  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section    Nominal stranding   Max. linear resistance at 20°C (red copper core)   Nominal thickness of insulating sheath    Nominal outer diameter    Approx. linear weight   
    [mm²] [Ω/km] [mm] [mm] [kg/km]
    0.25  14 x 0.15 or 8 x 0.20   78.6 0.6 1.9 5.8
    0.4  12 x 0.20   52.4 0.6 2 7.5
    0.5 16 x 0.20   39 0.6 2.1 8.5
    0.6 19 x 0.20   32.8 0.6 2.2 9.6
    0.75 24 x 0.20   26 0.6 2.4 11.5
    1 32 x 0.20   19.5 0.6 2.5 14.2
    1.5 30 x 0.25   13.3 0.6 2.8 19.8
    2.5 50 x 0.25   7.98 0.7 3.4 30.7
    4 56 x 0.30   4.95 0.8 4.2 48
    6 84 x 0.30   3.3 0.8 4.8 72.8
    10 80 x 0.40   1.91 1 6.4 123
    16 126 x 0.40   1.21 1.2 7.8 187
    25 196 x 0.40   0.78 1.4 9.6 290
    35 276 x 0.40   0.554 1.4 11 395
    50 396 x 0.40   0.386 1.6 13.2 553
    70 360 x 0.50   0.272 1.6 14.8 746
    95 485 x 0.50   0.206 1.8 17.4 1006
    120 608 x 0.50   0.161 1.8 19.4 1253
    150 756 x 0.50   0.129 2 21.4 1563
    185 944 x 0.50   0.106 2.2 23.9 1920
    240 1221 x 0.50   0.0801 2.2 26.4 2535
    300 1525 x 0.50   0.0641 2.4 29.9 3072
    400 2037 x 0.50   0.0486 2.6 34.2 4100


    Download:
  • Data Sheet
  • MC-ECS

    GENERAL
  • Continuous working temperatures: - 60°C to + 150°C, Peaks at + 230°C
  • Good resistance to thermal shock
  • Excellent ageing resistance
  • Good resistance to the usual chemical atmospheres
  • Halogen free cable
  • Working voltage: up to 600/1000 V
  • Test voltage: 2500 V

  • COLOUR
  • Colour of insulated conductors: refer to table below
  • Outer sheath: brick red, black, white
  • Other colours: consult us

  • PACKAGING
  • 100m Rolls, spools or drums

    OPTIONS
  • Please consult OBA about these options.
  • Red copper core
  • Nickel-plated copper core
  • Galvanized steel outer shielding
  • Silicone-coated fibreglass outer braid
  • Fibreglass braid and galvanized steel shielding

  • APPLICATIONS
  • All wiring in hot environments up to 150°C
  • Wiring in metal industry, glassworks, etc
  • Wiring in furnaces, ovens, thermoplastics and rubber machines, welding sets, etc
  • Lighting, floodlights, etc
  • CONDUCTOR COLOUR CODING - IEC 446
     Number    With earthing wire    Without earthing wire  
     2    -   brown - blue  
     3    green/yellow - brown - blue    black - brown - blue  
     4    green/yellow - black - brown - blue    black - brown - blue - grey or black  
     5    green/yellow - black - brown - blue - grey or black    black - brown - blue - 2 grey or black numbered  
     6    green/yellow - black - brown - blue - 2 grey or black numbered    black - brown - blue - 3 grey or black numbered  
     7    green/yellow - black - brown - blue - 3 grey or black numbered    black - brown - blue - 4 grey or black numbered  
       etc.    etc.  
       Option: for 6 or more conductors    
       green/yellow and numbered greys or blacks    numbered greys or blacks  

    Download:
  • Data Sheet
  • ECSP

    GENERAL
  • Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
  • Good resistance to thermal shock and UV
  • Excellent ageing resistance.
  • Good resistance to ozone and the corona effect
  • Excellent mechanical strength
  • Halogen free cable
  • Bending radius ≈ 5 x Diameter
  • Compatible with most impregnation varnishes.
  • Working voltage:
  • cross-section <10 mm² 450/750 V
  • cross-section <10 mm² 600/1000 V
  • Test voltage:
  • cross-section <10 mm² 2500 V
  • cross-section <10 mm² 3500 V

    COLOUR

  • 0.5 to 6 mm²: all colours
  • 10 to 400 mm²: black other colours on request

  • PACKAGING
  • 100m Rolls, spools or drums
  • OPTIONS
    Please consult OBA about these options.

  • Extra-flexible cores
  • Other cross-sections and flexibility classes: consult OBA
  • APPLICATIONS

  • Wiring of rotating machines: motors, alternators, generators
  • Wiring of static machines: transformers, inductors, inverters, choppers
  • Shipbuilding and railway construction
  • Power supply

  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section    Nominal stranding   Max. linear resistance at 20°C (red copper core)   Nominal outer diameter    Approx. linear weight    
    [mm²]  [Ω/km] [mm] [kg/km]
     0.25    8 x 0.20    78.6    1.8    5.30  
     0.5    16 x 0.20    39.0    2.0    8.00  
     0.75    24 x 0.20    26.0    2.2    10.9  
     1    32 x 0.20    19.5    2.3    13.4  
     1.5    30 x 0.25    13.3    2.7    19.8  
     2.5    50 x 0.25    7.98    3.4    30.7  
     4    56 x 0.30    4.95    4.2    48.0  
     6    84 x 0.30    3.30    5.2    73.0  
     10    80 x 0.40    1.91    7.0    129  
     16    126 x 0.40    1.21    8.6    198  
     25    196 x 0.40    0.78    10.4    295  
     35    276 x 0.40    0.554    11.9    399  
     50    396 x 0.40    0.386    14.1    562  
     70    360 x 0.50    0.272    15.9    759  
     95    485 x 0.50    0.206    18.2    1024  
     120    608 x 0.50    0.161    20.3    1275  
     150    756 x 0.50    0.129    22.8    1587  
     185    944 x 0.50    0.106    24.8    1952  
     240    1221 x 0.50    0.0801    28.8    2560  
     300    1525 x 0.50    0.0641    31.5    3095  
     400    2037 x 0.50    0.0486    35.4    5130  

    Download:
  • Data Sheet
  • Silicoul 1.1 kV

    GENERAL

  • Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
  • Good resistance to thermal shock and UV
  • Excellent ageing resistance
  • Good resistance to ozone and the corona effect
  • Excellent mechanical strength
  • Bending radius ≈ 5 x Diameter
  • Lloyds approved
  • Compatible with most impregnation varnishes
  • Working voltage: 1.1 kV. Test voltage: 3.5 kV. Max permissible current: consult our technical departments

    COLOUR
  • All cross-sections: yellow

  • PACKAGING
  • 100m Rolls, spools or drums

  • OPTIONS
  • UL/CSA approval: 1.1kV, style 3661
  • Without reinforcing braid
  • Other cross-sections: consult OBA

  • APPLICATIONS
  • Wiring of rotating machines: motors, alternators, generators
  • Wiring of static machines: transformers, inductors, inverters, choppers
  • Shipbuilding and railway construction
  • Power supply
  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section   Nominal stranding   Max. linear resistance at 20°C (red copper core)   Nominal outer diameter    Approx. linear weight    
    [mm²] [Ω/km] [mm] [kg/km]
    1.5 30 x 0.25   13.7 3.8 29.0
    2.5 50 x 0.25   8.21 4.3 37.8
    4 56 x 0.30   5.09 4.9 58.5
    6 84 x 0.30   3.39 6.0 76.6
    10 80 x 0.40   1.95 7.0 121
    16 126 x 0.40   1.24 8.6 178
    25 196 x 0.40   0.795 10.4 273
    35 276 x 0.40   0.565 11.9 376
    50 396 x 0.40   0.393 14.1 534
    70 360 x 0.50   0.277 15.9 738
    95 485 x 0.50   0.210 18.2 970
    120 608 x 0.50   0.164 20.3 1220
    150 756 x 0.50   0.132 22.8 1520
    185 944 x 0.50   0.108 24.8 1850
    240 1221 x 0.50   0.0817 28.8 2420
    300 1525 x 0.50   0.0654 31.5 3095
    400 2037 x 0.50   0.0495 34.6 4130

    Download:
  • Data Sheet
  • Silicoul 3.7 kV

    GENERAL

  • Continuous working temperatures: -60°C to +180°C, Peaks at +230°C
  • Good resistance to thermal shock and UV
  • Excellent ageing resistance
  • Good resistance to ozone and the corona effect
  • Excellent mechanical strength
  • Bending radius ≈ 5 x Diameter
  • Lloyds approved
  • Compatible with most impregnation varnishes
  • Working voltage: 4.2 kV

    COLOUR
  • All cross-sections: brown

  • PACKAGING
  • 100m Rolls, spools or drums

  • OPTIONS
  • UL/CSA approval: 4.2 kV, style 3662
  • Without reinforcing braid
  • Other cross-sections: consult OBA

  • APPLICATIONS
  • Wiring of rotating machines: motors, alternators, generators
  • Wiring of static machines: transformers, inductors, inverters, choppers
  • Shipbuilding and railroad construction
  • Power supply
  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section   Nominal stranding   Max. linear resistance at 20°C  Nominal outer diameter    Approx. linear weight    
    [mm²] [Ω/km] [mm] [kg/km]
    2.5 50 x 0.25   8.21 6.2 57.0
    4 56 x 0.30   5.09 6.8 75.0
    6 84 x 0.30   3.39 7.8 102
    10 80 x 0.40   1.95 9.0 150
    16 126 x 0.40   1.24 10.2 212
    25 196 x 0.40   0.795 11.8 305
    35 276 x 0.40   0.565 13.2 413
    50 396 x 0.40   0.393 15.4 575
    70 360 x 0.50   0.277 17.0 782
    95 485 x 0.50   0.21 19.8 1030
    120 608 x 0.50   0.164 21.8 1290
    150 756 x 0.50   0.132 24.0 1580
    185 944 x 0.50   0.108 25.4 1890
    240 1221 x 0.50   0.0817 29.2 2451
    300 1525 x 0.50   0.0654 31.8 3120
    400 2037 x 0.50   0.0495 35.8 4160

    Download:
  • Data Sheet
  • Silicoul 6.6 kV

    GENERAL

  • Continuous working temperatures: -60°C to +180°C, Peaks at +230°C
  • Good resistance to thermal shock and UV
  • Excellent ageing resistance
  • Good resistance to ozone and the corona effect
  • Excellent mechanical strength
  • Bending radius ≈ 5 x Diameter
  • Lloyds approved
  • Compatible with most impregnation varnishes
  • Working voltage: 7.2 kV
  • Test voltage: 15 kV
  • Max. permissible current: consult OBA

    COLOUR
  • All cross-sections: grey

  • PACKAGING
  • 100m Rolls, spools or drums

  • OPTIONS
  • UL/CSA approval: 7.2 kV, style 3663
  • Without reinforcing braid
  • Other cross-sections: consult OBA

  • APPLICATIONS
  • Wiring of rotating machines: motors, alternators, generators
  • Wiring of static motors: transformers, inductors, inverters, choppers
  • Shipbuilding and railway construction
  • Power supply
  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section   Nominal stranding   Max. linear resistance at 20°C (red copper core)   Nominal outer diameter    Approx. linear weight    
    [mm²]  [Ω/km] [mm] [kg/km]
    4 56 x 0.30   5.09 8.2 95.0
    6 84 x 0.30   3.39 9.1 120
    10 80 x 0.40   1.95 10.3 172
    16 126 x 0.40   1.24 11.5 238
    25 196 x 0.40   0.795 13.0 330
    35 276 x 0.40   0.565 14.6 440
    50 396 x 0.40   0.393 16.7 612
    70 360 x 0.50   0.277 18.3 825
    95 485 x 0.50   0.210 20.5 1060
    120 608 x 0.50   0.164 22.6 1315
    150 756 x 0.50   0.132 24.9 1630
    185 944 x 0.50   0.108 26.4 1935
    240 1221 x 0.50   0.0817 30.2 2510
    300 1525 x 0.50   0.0654 32.9 3180
    400 2037 x 0.50   0.0495 37.0 4210

    Download:
  • Data Sheet
  • Silicoul 13.8 kV

    GENERAL

  • Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
  • Good resistance to thermal shock and UV
  • Excellent ageing resistance
  • Good resistance to ozone and the corona effect
  • Excellent mechanical strength
  • Bending radius ≈ 5 x Diameter
  • Lloyds approved
  • Compatible with most impregnation varnishes
  • Working voltage: 15 kV
  • Test voltage: 30 kV
  • Max. permissible current: consult OBA

    COLOUR
  • All cross-sections: black

  • PACKAGING
  • 100m Rolls, spools or drums

  • OPTIONS
  • UL/CSA approval: 15 kV, style 3664
  • Without reinforcing braid
  • Other cross-sections: consult OBA

  • APPLICATIONS
  • Wiring of rotating machines: motors, alternators, generators
  • Wiring of static machines: transformers, inductors, inverters, choppers
  • Shipbuilding and railway construction
  • Power supply
  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section    Nominal stranding   Max. linear resistance at 20°C (red copper core)   Nominal outer diameter    Approx. linear weight    
    [mm²] [Ω/km]  [mm] [kg/km]
    6 84 x 0.30   3.39 11.8 175
    10 80 x 0.40   1.95 13.0 232
    16 126 x 0.40   1.24 14.2 303
    25 196 x 0.40   0.795 15.7 407
    35 276 x 0.40   0.565 17.2 522
    50 396 x 0.40   0.393 18.9 690
    70 360 x 0.50   0.277 20.7 907
    95 485 x 0.50   0.210 22.7 1160
    120 608 x 0.50   0.164 24.7 1415
    150 756 x 0.50   0.132 27.4 1758
    185 944 x 0.50   0.108 28.9 2050
    240 1221 x 0.50   0.0817 32.7 2660
    300 1525 x 0.50   0.0654 35.3 3330
    400 2037 x 0.50   0.0495 39.6 4360

    Download:
  • Data Sheet
  • Varpren F

    GENERAL

  • Working temperature: -50°C to +155°C,
  • Peak temperature: +170°C
  • Good compatibility with class F varnishes
  • Good resistance to atmospheric agents:
  • UV, Ozone, Oxygen
  • Excellent tearing resistance
  • Halogen free polyolefin elastomer
  • Bending radius ≈ 5 x Diameter
  • Nominal voltage: 600/1000 V
  • Test voltage: 2500 V

  • PACKAGING
  • 100m Rolls, spools or drums

  • APPLICATIONS
  • Electrical motor applications
  • Rotating and static machines
  • Lighting
  • Power supplies, electrotechnical equipment
  • Shipbuilding and railways construction
  • CORE ISOLATION / INSULATION 
    Cross-section   Stranding   Core resistance (20 °C) Wall thickness   Outer diameter   Weight  
    mm²     Ω/km   mm   ø mm   kg/km  
    0.25 8 x 0.20   80.2 0.6 1.95 4
    0.5 16 x 0.20   40.1 0.6 2.2 9
    0.75 24 x 0.20   26.7 0.6 2.4 12
    1 32 x 0.20   20 0.6 2.5 14
    1.5 30 x 0.25   13.7 0.6 3 21
    2.5 50 x 0.25   8.21 0.7 3.6 30.5
    4 56 x 0.30   5.09 0.8 4.3 46.5
    6 84 x 0.30   3.39 0.8 4.9 73
    10 80 x 0.40   1.95 1 6.6 125
    16 126 x 0.40   1.24 1 7.7 185
    25 196 x 0.40   0.795 1.2 9.6 280
    35 276 x 0.40   0.565 1.2 10.7 370
    50 396 x 0.40   0.393 1.4 12.6 540
    70 360 x 0.50   0.277 1.4 14.9 730
    95 485 x 0.50   0.21 1.6 17.2 990
    120 608 x 0.50   0.164  1.6    -  1250
    150 756 x 0.50   0.132 1.8  -  1650
    185 944 x 0.50   0.108 2  -  1750

    Download:
  • Data Sheet
  • Varpren MVA

    GENERAL

  • Working temperature: -50°C to +150°C
  • Peak temperature: +170°C
  • Adequate resistance to thermal shocks
  • Good ageing in hot environments
  • Good resistance to atmospheric agents: UV, Ozone, Oxygen
  • Excellent tearing resistance
  • Halogen free cable
  • Fire retardant
  • Bending radius ≈ 10 x Diameter
  • Nominal voltage: 600/1000 V
  • Test voltage: 2500 V

  • PACKAGING
  • 100m Rolls, spools or drums

  • APPLICATIONS
  • Electrical motor applications
  • Rotating and static machines
  • Lighting
  • Power supplies, electrotechnical equipment
  • Shipbuilding and railways construction

  • NB: MVA cables can be made to order in 2 to 5 cores in sizes up to 2.5 mm2

    CORE INSULATION
     Cross-section    Stranding    Core resistance (20 °C)     Wall thickness    Outer diameter  
     mm²      Ω/km    mm    ø mm  
     2 x 0.5 16 x 0.20 40.1 0.7 6.7
    3 x 0.5 16 x 0.20 40.1 0.7 7.1
    4 x 0.5 16 x 0.20 40.1 0.8 7.8
    5 x 0.5 16 x 0.20   40.1 0.8 8.4
    2 x 0.75 24 x 0.20 26.7 0.8 7.2
    3 x 0.75 24 x 0.20 40.1 0.8 7.7
    4 x 0.75   24 x 0.20   40.1 0.9 8.5
    5 x 0.75   24 x 0.20   40.1 1 9.3
    2 x 1   32 x 0.20   20 0.8 7.5
    3 x 1   32 x 0.20   20 0.9 8.1
    4 x 1   32 x 0.20   20 0.9 8.7
    5 x 1   32 x 0.20   20 1 9.7
    2 x 1.5   30 x 0.25   13.7 1 8.9
    3 x 1.5   30 x 0.25   13.7 1 9.3
    4 x 1.5   30 x 0.25   13.7 1 10.1
    5 x 1.5   30 x 0.25   13.7 1 11
    2 x 2.5   50 x 0.25   8.21 1 9.9
    3 x 2.5   50 x 0.25   8.21 1 10.5
    4 x 2.5   50 x 0.25   8.21 1 11.6
    5 x 2.5   50 x 0.25   8.21 1 12.8

    Download:
  • Data Sheet
  • NVS and NVSL

    GENERAL

  • Continuous working temperatures: -60°C to + 350°C,
  • Peaks at + 400°C
  • Good resistance to thermal shock
  • Excellent ageing resistance
  • Good resistance to the usual chemical atmospheres
  • Working voltage: 300/500 V
  • Test voltage: 2000 V

  • COLOUR
  • Standard colour: brown.
  • All plain colours or with coloured spiral tracers on request, including green/yellow

  • PACKAGING
  • 100m Rolls, spools or drums

  • OPTIONS
  • Please consult OBA about these options.
  • Teflon-coated (Teflon® PTFE varnish) fibreglass
  • braid
  • Multi-conductor assemblies - under silicone-coated fibreglass braid
    - under galvanized steel shielding braid
  • Other cross-sections and flexibility classes: consult OBA

  • APPLICATIONS
  • Wiring of heating elements, cartridges, bands and hot plates
  • Domestic electrical heating appliances, professional kitchens and ovens
  • Machines for thermoplastics and rubber, etc
  • Furnaces and industrial ovens


  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section   Nominal stranding   Max. linear resistance at 20°C (red copper core)   Nominal outer diameter    Approx. linear weight    
    [mm²]  [??] [Ω/km] [mm] [kg/km]
    SILICABLE® NVS
    0.25 4 x 0.30   351 1.9 6.50
    0.5 7 x 0.30   178 2.1 8.70
    0.75 11 x 0.30   114 2.4 11.9
    1 14 x 0.30   91.0 2.5 14.5
    1.5 21 x 0.30   61.0 2.8 20.5
    2.5 35 x 0.30   36.5 3.2 32.2
    4 56 x 0.30   23.8 4.3 50.1
    6 84 x 0.30   15.1 4.8 72.3
    10 140 x 0.30   8.7 6.8 131
    16 228 x 0.30   5.8 8.2 206
    25 354 x 0.30   3.6 10.1 323
    35 495 x 0.30   2.6 12.0 423
    50 707 x 0.30   1.9 13.2 591
    SILICABLE® NVSL (reduced outer diameters)
    0.22 7 x 0.20   395 1.2 ± 0.15   5.4
    0.25 8 x 0.20   351 1.3 ± 0.15   6
    0.34 11 x 0.20   257 1.4 ± 0.15   7.7
    0.5 7 x 0.30 or 16 x 0.20   178 1.6 ± 0.15   8.5
    0.6 9 x 0.30 or 19 x 0.20   140 1.7 ± 0.15   9.5
    0.75 11 x 0.30 or 24 x 0.20   115 1.8 ± 0.20   11.5
    1 14 x 0.30 or 32 x 0.20   91 2.1 ± 0.20   14
    1.5 21 x 0.30   61 2.5 ± 0.20   20
    2 28 x 0.30   46 2.9 ± 0.20   26
    2.5 35 x 0.30   36.5 3.1 ± 0.25   31.7
    4 56 x 0.30   23.8 3.6 ± 0.30   49

    Download:
  • Data Sheet
  • BM-NVS

    GENERAL

  • Continuous working temperatures: - 60°C to + 350°C,
  • Peaks at + 400°C
  • Good resistance to thermal shock
  • Excellent ageing resistance
  • Working voltage: 300/500 V
  • Test voltage: 2000 V

  • COLOUR
  • Colour-coding of insulated conductors (main products):3: Brown - Blue - Green/Yellow (earthing wire), 4: Black - Brown - Blue - Green/Yellow (earthing wire), 5: Black - Black - Brown - Blue - Green/Yellow(earthing wire)
  • Outer braid with or without coloured spiral tracers

  • PACKAGING
  • 100m Rolls

  • OPTIONS
  • Please consult OBA about these options
  • Earthing wire in nickel-plated copper
  • All conductors in nickel-plated copper
  • Outer braid in stainless steel
  • Other cross-sections and conductor number: consult OBA

  • APPLICATIONS
  • Wiring of resistance, cartridges, hot-plates and heater bands


  • INSULATED CONDUCTORS CABLE
    Nominal cross-section    Nominal stranding   Approx. outer diameter    Approx. outer diameter  Approx. linear weight  
    mm² mm mm  kg/km
    3 x 0.75   11 x 0.30   2.4 6.4 81.0
    4 x 0.75   11 x 0.30   2.4 7.0 98.0
    5 x 0.75   11 x 0.30   2.4 7.4 116
    3 x 1   14 x 0.30   2.5 6.7 96.0
    4 x 1   14 x 0.30   2.5 7.3 114
    5 x 1   14 x 0.30   2.5 7.8 132
    3 x 1.5   21 x 0.30   2.8 7.2 117
    4 x 1.5   21 x 0.30   2.8 7.6 140
    5 x 1.5   21 x 0.30   2.8 9.0 169
    3 x 2.5   35 x 0.30   3.2 8.2 157
    4 x 2.5   35 x 0.30   3.2 9.6 199
    5 x 2.5   35 x 0.30   3.2 10.8 239
    3 x 4   56 x 0.30   4.3 10.6 228
    4 x 4   56 x 0.30   4.3 11.6 286
    5 x 4   56 x 0.30   4.3 13.2 346
    3 x 6   84 x 0.30   4.8 11.7 303
    4 x 6   84 x 0.30   4.8 12.7 380
    5 x 6   84 x 0.30   4.8 13.8 462
    3 x 10   140 x 0.30   6.6 17.0 517
    4 x 10   140 x 0.30   6.6 19.2 664
    5 x 10   140 x 0.30   6.6 23.0 824

    Download:
  • Data Sheet
  • NVAS

    GENERAL

  • Continuous working temperatures: - 60°C to + 450°C, Peaks at + 550°C
  • Excellent resistance to thermal shock
  • Excellent ageing resistance
  • Good resistance to the usual chemical atmospheres
  • Lloyds approved
  • Working voltage: 300/500 V
  • Test voltage: 2000 V

  • COLOUR
  • Standard colour: grey
  • Any colour on request, including green/yellowers

  • PACKAGING
  • 100m Rolls, spools or drums

  • OPTIONS
  • Please consult OBA about these options.
  • Multiconductor assemblies - under a braided mineral fibre sheath, - under a stainless steel shielding braid
  • Other cross-sections and flexibility classes: consult us
  • Very high temperature fibreglass insulating sheath: (outer diameters identical to type NVS)

  • APPLICATIONS
  • Wiring of heating elements, cartridges, bands and hot plates
  • Wiring of domestic electrical heating appliances, professional kitchens and ovens
  • Machines for thermoplastics and rubber, etc
  • Furnaces and industrial ovens
  • Heavy industry: foundries, steelworks, glassworks, etc

  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section    Nominal stranding   Max. linear resistance at 20°C (nickel core)   Nominal outer diameter   Approx. linear weight    
    mm² Ω/km mm  kg/km
    0.25 4 x 0.30   351 2.2 6.5
    0.5 7 x 0.30   178 2.5 8.7
    0.75 11 x 0.30   114 2.7 11.9
    1 14 x 0.30   91 3.2 14.5
    1.5 21 x 0.30   61 3.4 20.5
    2.5 35 x 0.30   36.5 4 32.2
    4 56 x 0.30   23.8 4.5 50.1
    6 84 x 0.30   15.1 5.3 72.3
    10 140 x 0.30   8.7 8 130
    16 228 x 0.30   5.8 9 206
    25 354 x 0.30   3.6 10.6 323
    35 495 x 0.30   2.6 13.4 423
    50 707 x 0.30   1.9 14 590

    Download:
  • Data Sheet
  • TPT

    GENERAL

  • Continuous working temperatures: + 125°C (Class B)
  • Excellent resistance to freon R12, R22, R134a, R502 and refrigerating fluids
  • Excellent resistance to alcohols and solvents
  • Working voltage: 600 V. Test voltage: 2500 V

  • COLOUR
  • Plain white or white with coloured spiral tracers

  • PACKAGING
  • 100m Rolls, spools or drums

  • OPTIONS
  • Other cross-sections or flexibility classes: consult us

  • APPLICATIONS
  • Internal wiring of sealed motor units

  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section   Nominal stranding   Max. linear resistance at 20°C    Nominal outer diameter    Approx. linear weight    
    mm² Ω/km mm kg/km
    0.75 42 x 0.15   26.0 1.8 8.80
    1 32 x 0.20   19.5 1.9 11.2
    1.5 30 x 0.25   13.3 2.3 16.8
    2.5 50 x 0.25   7.98 2.8 29.2
    4 56 x 0.30   4.95 3.2 43.8
    6 84 x 0.30   3.30 3.8 65.0
    10 80 x 0.40   1.91 6.5 116
    16 126 x 0.40   1.21 7.5 181
    25 196 x 0.40   0.78 8.8 280
    35 276 x 0.40   0.55 10.1 385
    50 396 x 0.40   0.39 11.6 550

    Download:
  • Data Sheet
  • HT


    GENERAL
  • Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
  • Good resistance to thermal shock, excellent resistance to ageing
  • Good resistance to humidity
  • Excellent resistance to ozone and the corona effect
  • Does not spread flame or fire
  • Pulsed voltage: from 5 to 50 kV
  • ECS-HT-VDE: working voltage 1.8/3 kV

  • COLOUR
  • Main products: refer to table
  • Colour of silicone insulator: brick red, white, black or translucent. Other colours: consult us

  • OPTIONS
  • Teflon insulated cables
  • Longitudinal marking on silicone insulator: consult OBA
  • Pure nickel or nickel-plated copper conductor: consult OBA
  • Other cross-sections and flexibility classes: consult OBA
  • Applications requiring design of a specific cable: consult OBA

  • PACKAGING
  • 100m Rolls, spools, drums or SILIBOX®

  • APPLICATIONS
  • Ignition circuits, creation of electric arc
  • Piezo-electrics of domestic electrical appliances
  • Gas or fuel burners in boilers, and professional appliances
  • Neon electric signs
  • Burners in corrosive environments, near flames, molten glass or metal

  • CORE INSULATED WIRE
    Nominal c/section   Nominal stranding   Max. linear resistance at 20°C (tinned copper core)   Thickness of silicone insulating sheath  Nominal outer diameter  
    mm²  Ω/km mm mm 
      0.25 8 x 0.20 80.9 1.15 3
    0.34 7 x 0.25   59.2 1.1 3
    0.5 16 x 0.20 40.1 1 3
    (E)CS-HT  1 32 x 0.20   20 2.45 6.2
    1.5 30 x 0.25   13.7 3.2 8
    2.5 50 x 0.25   8.21 3.45 9
    4 56 x 0.30   5.09 3.7 10
    ECS-HT-VDE 1 32 x 0.20   20 1.3 3.9
    1.5 30 x 0.25   13.7 1.3 4.2
    (E)CSV-HT or (E)CSVRI-HT 0.34 7 x 0.25   59.2 0.9 3
    0.5 16 x 0.20 40.1 0.9 3.1
    (E)CSVCS-HT 1.34 19 x 0.30   15 2.75 7
    1.5 30 x 0.25   13.7 2.85 7.3
    CSABI-HT 1.5 30 x 0.25   13.7 3.2 10
    2.5 50 x 0.25 8.21 3.5 11
    4 56 x 0.30   5.09 3.7 12

    Download:
  • Data Sheet
  • EETFE


    GENERAL
  • Continuous working temperatures: -90°C to +155°C, Peaks at +180°C
  • Excellent resistance to aggressive chemical atmospheres
  • Excellent resistance to humidity and UV
  • Excellent mechanical strength
  • Working voltage: 450/750 V
  • Test voltage: 2500 V

  • COLOUR
  • All colours, including translucent

  • OPTIONS
  • Please consult OBA about these options.
  • Nickel-plated copper core
  • Silver-plated copper core
  • Pure nickel core
  • Cross-sections up to 240 mm²: consult OBA
  • Other flexibility classes: consult OBA

  • PACKAGING
  • 100m Rolls, spools, drums or SILIBOX®

  • APPLICATIONS
  • Wiring of rotating machines, class F
  • Wiring in household appliances, electronics
  • Wiring in hot or cold environments (cryogenics)
  • Wiring in aggressive atmospheres (humid, chemical, etc.)
  • Wiring that requires compact fitting and excellent mechanical strength

  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section    Nominal stranding   Nominal diameter   Max. linear resistance at 20 °C (red copper wire)   Nominal insulation thickness  Outer diameter
    mm
    Approx.
    linear weight
    mm² mm Ω/km mm kg/km
    0.05 7 x 0.10   0.30 373 0.17 0.65 0.90
    0.12 7 x 0.15   0.45 161 0.17 0.80 1.70
    0.15 19 x 0.10   0.50 136 0.2 0.90 2.10
    0.22 7 x 0.20   0.60 89.9 0.2 1.00 2.80
    0.25 19 x 0.13   0.65 79.9 0.2 1.05 3.20
    0.34 7 x 0.25   0.75 58.9 0.2 1.15 4.10
    0.34 19 x 0.15   0.75 58.9 0.2 1.15 4.10
    0.5 7 x 0.30   0.90 39.6 0.2 1.30 5.70
    0.5 16 x 0.20   0.90 39.0 0.2 1.30 5.70
    0.6 19 x 0.20   1.00 32.8 0.2 1.40 6.70
    0.75 24 x 0.20   1.05 26.0 0.2 1.45 7.82
    0.93 19 x 0.25   1.25 21.0 0.25 1.70 10.2
    1 32 x 0.20   1.20 19.5 0.25 1.70 10.6
    1.34 19 x 0.30   1.40 14.6 0.25 1.90 13.9
    1.5 30 x 0.25   1.45 13.3 0.3 1.95 15.2
    2.5 50 x 0.25   1.90 7.98 0.3 2.50 25.6
    4 56 x 0.30   2.55 4.95 0.3 3.30 41.4
    6 84 x 0.30   3.10 3.30 0.35 3.90 61.7
    10 80 x 0.40   4.40 1.91 0.4 5.20 100
    16 126 x 0.40   5.40 1.21 0.4 6.20 157

    Download:
  • Data Sheet
  • EPFA


    GENERAL
  • Continuous working temperatures: -90°C to +260°C, Peaks at +280°C
  • Excellent resistance to aggressive chemical atmospheres
  • Excellent resistance to humidity and UV
  • Excellent mechanical strength
  • Working voltage: 450/750 V
  • Test voltage: 2500 V

  • COLOUR
  • All colours, including translucent

  • OPTIONS
  • Please consult OBA about these options.
  • Nickel-plated copper core
  • Silver-plated copper core
  • Pure nickel core
  • MFA fluorinated polymer insulator (- 90°C to + 240°C)
  • Cross-sections up to 240 mm²: consult OBA
  • Other flexibility classes: consult OBA

  • PACKAGING
  • 100m Rolls, spools, drums or SILIBOX®

  • APPLICATIONS
  • Wiring in household appliances, electronics
  • Wiring in hot and cold environments (cryogenics)
  • Wiring in aggressive environments (humid, chemical, etc.)
  • Wiring that requires compact fitting and excellent mechanical strength

  • CORE INSULATED WIRE OR CABLE
    Nominal cross-section    Nominal stranding   Nominal diameter   Max. linear resistance at 20 °C (red copper wire)   Nominal insulation thickness  Outer diameter Approx.
    linear weight
    mm² mm Ω/km mm mm kg/km
    0.05 7 x 0.10   0.30 373 0.17 0.65 1.0
    0.12 7 x 0.15   0.45 161 0.17 0.80 1.8
    0.15 19 x 0.10   0.50 136 0.20 0.90 2.3
    0.22 7 x 0.20   0.60 89.9 0.20 1.00 3.0
    0.25 19 x 0.13   0.65 79.9 0.20 1.05 3.4
    0.34 7 x 0.25   0.75 58.9 0.20 1.15 4.3
    0.34 19 x 0.15 0.75 58.9 0.20 1.15 4.3
    0.5 7 x 0.30   0.90 39.6 0.20 1.30 6.0
    0.5 16 x 0.20   0.90 39.0 0.20 1.30 6.0
    0.6 19 x 0.20   1.00 32.8 0.20 1.40 7.0
    0.75 24 x 0.20   1.05 26.0 0.20 1.45 8.0
    0.93 19 x 0.25   1.25 21.0 0.25 1.70 10.6
    1 32 x 0.20   1.20 19.5 0.25 1.70 11.0
    1.34 19 x 0.30   1.40 14.6 0.25 1.90 14.3
    1.5 30 x 0.25   1.45 13.3 0.30 1.95 15.6
    2.5 50 x 0.25   1.90 7.98 0.30 2.50 26.3
    4 56 x 0.30   2.55 4.95 0.30 3.30 42.3
    6 84 x 0.30   3.10 3.30 0.35 3.90 63.5
    10 80 x 0.40   4.40 1.91 0.40 5.20 103.0
    16 126 x 0.40 5.40 1.21 0.40 6.20 159.0

    Download:
  • Data Sheet
  • Thermocouple cables (COUPLIX)


    GENERAL
    Thermoelectric effect (Seebeck): The thermoelectric effect consists of the production of an electromotive force (emf) created by the temperature difference between two different metal or alloy junctions making up the same circuit.

    Thermocouple: A thermoelectric couple is formed by a pair of conductors of different types connected at their ends, to provide a complete circuit that can be used for measuring temperature by thermoelectric effect.

    Extension Cables: Extension cables are manufactured with wires of the same composition as the wires of the corresponding couples. They are coded with the letter "X" placed after the thermocouple code, for example "JX".

    Compensation Cables: Compensation cables are manufactured with wires of different stranding or material to the wires of the corresponding thermocouples. They are marked by the letter "C" placed after the thermocouple code, for example "KC". Different alloys can be used for the same type of thermocouple.

    Note: All stocked thermocouple cables are supplied in A.N.S.I. colour code.

    COLOUR
  • All colours, including translucent

    OPTIONS
  • Other cross-sections and stranding: consult OBA
  • Other insulation: consult OBA
  • Multipair cables, with or without individual screen with or without general screen: consult OBA
  • Imposed maximum outer diameters: consult OBA
  • Hybrid cables: consult OBA
  • APPLICATIONS
    Anywhere to measure heat

    Insulation
    No. of Pairs  Nominal Cross Section Conductor Sheath Continuous working temperature of insulation Sheath Colour
    [mm²]
    Type J Single Pair
    J-BIMV-VS 1 0.22 Fibreglass Fibreglass/Stainless Steel Braid -60ºC to + 400ºC Stainless Steel
    J-M5-5 1 0.22 PFA PFA -190ºC to +260ºC Brown
    J-MV-VS 1 0.22 Fibreglass Fibreglass -60ºC to +400ºC Brown
    Type J Single Pair Extension
    JX1-MY2-Y2 1 0.22 PVC 105C PVC 105C -30ºC to +105ºC Black
    Type K Single Pair
    K-BIM5-5 1 0.22 PFA PFA/Stainless Steel Braid -60ºC to +260ºC Stainless Steel
    K-BIMV-VS 1 0.22 Fibreglass Fibreglass/ Stainless Steel Braid -60ºC to +400ºC Stainless Steel 
    K-M5-5 1 0.22 PFA PFA -190ºC to +260ºC Brown
    K-MV-VS 1 0.22 Fibreglass Fibreglass -60ºC to +400ºC Brown
    Type K Single Pair Extension
    KX1-MY2-Y2 1 0.22 PVC 105C PVC 105C -30ºC to +105ºC Yellow
    Type T Single Pair
    T-M5-5 1 0.22 PFA PFA -190ºC to +260ºC Brown
    Type K Multi Pair Extension (Overall screened plus drain wire)
    KX1-MY2BAL-M-Y2 1 0.22 PVC 105C PVC 105C -30C to +105C Yellow
    KX1-MY2BAL-M-Y2 4 0.22 PVC 105C PVC 105C -30C to +105C Yellow
    KX1-MY2BAL-M-Y2 6 0.22 PVC 105C PVC 105C -30C to +105C Yellow
    KX1-MY2BAL-M-Y2 8 0.22 PVC 105C PVC 105C -30C to +105C Yellow
    KX1-MY2BAL-M-Y2 12 0.22 PVC 105C PVC 105C -30C to +105C Yellow
    KX1-MY2BAL-M-Y2 24 0.22 PVC 105C PVC 105C -30C to +105C Yellow


    Download:
  • Data Sheet
  • RTD Cables (SONDIX)


    GENERAL
  • The electrical resistance of a metal conductor increases with temperature
  • This variation is reversible
  • Platinum is the metal most often used

  • COLOUR
  • Cables with 2, 3 or 4 conductors
  • Other number of conductors on request
  • Colour-coding:
    2 conductors: red/white
    3 conductors: red/red/white
    4 conductors: red/red/white/white
  • Standard colour of silicone sheaths: grey
  • Standard colour of FEP or PFA sheaths: white
  • Standard colour of outer fibreglass sheaths: white
  • Other colours on request
  • Types of core: red, tinned, silver-plated or nickel-plated copper
  • Outer diameters: consult OBA

    OPTIONS
  • Other number of conductors: consult OBA
  • Other cross-sections and conductor metals: consult OBA
  • High-performance insulation, for temperatures up to 850°C and above: consult OBA
  • Parallel assembly, flat cables: consult OBA
  • APPLICATIONS
    Cabling for platinum resistance temperature detectors

    PACKAGING
    Other types and conductor configurations can be made to order These cables are available in other pack sizes in multiples of 100m
    Insulation
    Nominal
    Cross
    Section
    [mm²]
    No. of Cores Insulation
    Type
    Insulation
    Conductor
    Sheath Continuous
    working
    temperature
    of insulation
    Sheath
    Colour
    Pack
    Size
    0.22 3 M5BAL-E5 PFA PFA -190°C to +260°C White 500m
    0.22 4 M5BAL-E5 PFA PFA -190°C to +260°C White 500m
    0.22 6 M5BAL-E5 PFA PFA -190°C to +260°C White 500m


    Download:

  • Data Sheet
  •