Cables
We have cables for every industry. Automotive, marine,
building, explosive, power flexes, welding flexes, garden
lighting, multicore, pool and solar cable, instrumentation
cable. High voltage, high temperature, high tension
cables, measurement cables, pyrometric cables, motor
lead, silicone insulated cables, multi-conductor cables,
safety cables.
Where it is important our we have cables that have UL,
IEC, CSA, DIN and Veritas approval.
Applications
Cables
RECS (SIE VDE)
ECS (SIF VDE)
MC-ECS
ECSP
Silicoul 1.1 kV
Silicoul 3.7 kV
Silicoul 6.6 kV
Silicoul 13.8 kV
Varpren F
Varpren MVA
NVS and NVSL
BM-NVS
NVAS
TPT
HT
EETFE
EPFA
Thermocouple cables (COUPLIX)
RTD Cables (SONDIX)
Cables
GENERAL
OBA supplies a wide range of specialized cables, not only for the electric motor industry, but also for other applications.
Our primary ranges are silicone, single core cables that are suitable for temperature ranges of -60°C to 180°C and -90°C to 450°C. This cable, suitable from -90°C to 450°C, is available in both single and multi-core types. Although the majority of these cables have copper conductors some are a nickel alloy for special applications.
Also available are specialized cables that are suitable for temperatures up to 1400°C.
In addition to the specialized range above cables for use in the following ranges of applications are available. For full detailed specifications please contact your nearest OBA office.
Low Voltage (Garden & Irrigation)
Data
Automotive
Marine
SELECTION
Click here to view the Quick Find chart providing key information on the most common cables available from OBA, however if what you want is not on the list please ring your nearest OBA office.
Download:
Data Sheet
RECS (SIE VDE)
GENERAL
Continuous working temperatures:
- 60°C to + 180°C, Peaks at + 230°C
Good resistance to thermal shock and UV
Excellent ageing resistance
Halogen free cable
Working voltage:
cross-section <10 mm² 450/750 V
cross-section >10 mm² 600/1000 V
Test voltage: 2000 V
COLOUR
0.25 to 6 mm2: all colours, including two-colour
10 to 95 mm2: white, black, other colours on request
PACKAGING
100m Rolls, spools, drums or SILIBOX®
OPTIONS
Please consult OBA about these options.
Mechanical outer shielding:
in galvanized steel
in stainless steel
APPLICATIONS
Wiring of domestic electrical heating appliances
Rotating machines (class H)
Lighting
Industrial wiring for hot environments
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20 °C (red copper wire) |
Nominal thickness of
Insulating sheath |
Nominal
outer diameter |
Approx.
linear weight |
| [mm²] |
|
[Ω/km] |
[mm] |
[mm] |
[kg/km] |
| 0.25 |
1 x 0.56 |
74.5 |
0.6 |
1.7 |
5.30 |
| 0.5 |
1 x 0.80 |
36.0 |
0.6 |
2.0 |
7.70 |
| 0.75 |
1 x 0.98 |
24.5 |
0.6 |
2.2 |
10.7 |
| 1 |
1 x 1.13 |
18.1 |
0.6 |
2.4 |
12.8 |
| 1.5 |
1 x 1.38 |
12.1 |
0.6 |
2.6 |
18.0 |
| 2.5 |
1 x 1.78 |
7.41 |
0.7 |
3.2 |
28.9 |
| 4 |
1 x 2.26 |
4.61 |
0.8 |
3.9 |
45.4 |
| 6 |
1 x 2.76 |
3.08 |
0.8 |
4.4 |
64.5 |
| 10 |
7 x 1.38 |
1.83 |
1.1 |
6.4 |
121 |
| 16 |
7 x 1.70 |
1.15 |
1.2 |
7.5 |
183 |
| 25 |
7 x 2.14 |
0.727 |
1.6 |
9.6 |
285 |
| 35 |
7 x 2.52 |
0.524 |
1.8 |
11.2 |
390 |
| 50 |
19 x 1.78 |
0.387 |
2.2 |
13.3 |
550 |
| 70 |
19 x 2.14 |
0.268 |
2.4 |
15.5 |
740 |
| 95 |
19 x 2.52 |
0.193 |
2.6 |
17.8 |
1000 |
Download:
Data Sheet
ECS (SIF - VDE)
GENERAL
Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
Good resistance to thermal shock and UV
Excellent ageing resistance
Halogen free cable
Working voltage:
cross-section <10 mm² 450/750 V
cross-section >10 mm² 600/1000 V
Test voltage: 2000 V
COLOUR
0.25 to 6 mm²: all colours, including two-colour
10 to 400 mm²: white, black, other colours on request
PACKAGING
Rolls, spools, drums or SILIBOX®
OPTIONS
Please consult OBA about these options.
Nickel-plated copper core
Pure nickel core
Mechanical outer shielding:
in galvanized steel
in stainless steel
APPLICATIONS
Wiring of domestic electrical heating appliances
Rotating machines (class H)
Urban lighting
Industrial wiring in hot environments
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C (red copper core) |
Nominal thickness of insulating sheath |
Nominal outer diameter |
Approx. linear weight |
| [mm²] |
|
[Ω/km] |
[mm] |
[mm] |
[kg/km] |
| 0.25 |
14 x 0.15 or 8 x 0.20 |
78.6 |
0.6 |
1.9 |
5.8 |
| 0.4 |
12 x 0.20 |
52.4 |
0.6 |
2 |
7.5 |
| 0.5 |
16 x 0.20 |
39 |
0.6 |
2.1 |
8.5 |
| 0.6 |
19 x 0.20 |
32.8 |
0.6 |
2.2 |
9.6 |
| 0.75 |
24 x 0.20 |
26 |
0.6 |
2.4 |
11.5 |
| 1 |
32 x 0.20 |
19.5 |
0.6 |
2.5 |
14.2 |
| 1.5 |
30 x 0.25 |
13.3 |
0.6 |
2.8 |
19.8 |
| 2.5 |
50 x 0.25 |
7.98 |
0.7 |
3.4 |
30.7 |
| 4 |
56 x 0.30 |
4.95 |
0.8 |
4.2 |
48 |
| 6 |
84 x 0.30 |
3.3 |
0.8 |
4.8 |
72.8 |
| 10 |
80 x 0.40 |
1.91 |
1 |
6.4 |
123 |
| 16 |
126 x 0.40 |
1.21 |
1.2 |
7.8 |
187 |
| 25 |
196 x 0.40 |
0.78 |
1.4 |
9.6 |
290 |
| 35 |
276 x 0.40 |
0.554 |
1.4 |
11 |
395 |
| 50 |
396 x 0.40 |
0.386 |
1.6 |
13.2 |
553 |
| 70 |
360 x 0.50 |
0.272 |
1.6 |
14.8 |
746 |
| 95 |
485 x 0.50 |
0.206 |
1.8 |
17.4 |
1006 |
| 120 |
608 x 0.50 |
0.161 |
1.8 |
19.4 |
1253 |
| 150 |
756 x 0.50 |
0.129 |
2 |
21.4 |
1563 |
| 185 |
944 x 0.50 |
0.106 |
2.2 |
23.9 |
1920 |
| 240 |
1221 x 0.50 |
0.0801 |
2.2 |
26.4 |
2535 |
| 300 |
1525 x 0.50 |
0.0641 |
2.4 |
29.9 |
3072 |
| 400 |
2037 x 0.50 |
0.0486 |
2.6 |
34.2 |
4100 |
Download:
Data Sheet
MC-ECS
GENERAL
Continuous working temperatures: - 60°C to + 150°C, Peaks at + 230°C
Good resistance to thermal shock
Excellent ageing resistance
Good resistance to the usual chemical atmospheres
Halogen free cable
Working voltage: up to 600/1000 V
Test voltage: 2500 V
COLOUR
Colour of insulated conductors: refer to table below
Outer sheath: brick red, black, white
Other colours: consult us
PACKAGING
100m Rolls, spools or drums
OPTIONS
Please consult OBA about these options.
Red copper core
Nickel-plated copper core
Galvanized steel outer shielding
Silicone-coated fibreglass outer braid
Fibreglass braid and galvanized steel shielding
APPLICATIONS
All wiring in hot environments up to 150°C
Wiring in metal industry, glassworks, etc
Wiring in furnaces, ovens, thermoplastics and rubber machines, welding sets, etc
Lighting, floodlights, etc
| CONDUCTOR COLOUR CODING - IEC 446 |
| Number |
With earthing wire |
Without earthing wire |
| 2 |
- |
brown - blue |
| 3 |
green/yellow - brown - blue |
black - brown - blue |
| 4 |
green/yellow - black - brown - blue |
black - brown - blue - grey or black |
| 5 |
green/yellow - black - brown - blue - grey or black |
black - brown - blue - 2 grey or black numbered |
| 6 |
green/yellow - black - brown - blue - 2 grey or black numbered |
black - brown - blue - 3 grey or black numbered |
| 7 |
green/yellow - black - brown - blue - 3 grey or black numbered |
black - brown - blue - 4 grey or black numbered |
| |
etc. |
etc. |
| |
Option: for 6 or more conductors |
|
| |
green/yellow and numbered greys or blacks |
numbered greys or blacks |
Download:
Data Sheet
ECSP
GENERAL
Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
Good resistance to thermal shock and UV
Excellent ageing resistance.
Good resistance to ozone and the corona effect
Excellent mechanical strength
Halogen free cable
Bending radius ≈ 5 x Diameter
Compatible with most impregnation varnishes.
Working voltage:
cross-section <10 mm² 450/750 V
cross-section <10 mm² 600/1000 V
Test voltage:
cross-section <10 mm² 2500 V
cross-section <10 mm² 3500 V
COLOUR
0.5 to 6 mm²: all colours
10 to 400 mm²: black other colours on request
PACKAGING
100m Rolls, spools or drums
OPTIONS
Please consult OBA about these options.
Extra-flexible cores
Other cross-sections and flexibility classes: consult OBA
APPLICATIONS
Wiring of rotating machines: motors, alternators, generators
Wiring of static machines: transformers, inductors, inverters, choppers
Shipbuilding and railway construction
Power supply
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C (red copper core) |
Nominal outer diameter |
Approx. linear weight |
| [mm²] |
|
[Ω/km] |
[mm] |
[kg/km] |
| 0.25 |
8 x 0.20 |
78.6 |
1.8 |
5.30 |
| 0.5 |
16 x 0.20 |
39.0 |
2.0 |
8.00 |
| 0.75 |
24 x 0.20 |
26.0 |
2.2 |
10.9 |
| 1 |
32 x 0.20 |
19.5 |
2.3 |
13.4 |
| 1.5 |
30 x 0.25 |
13.3 |
2.7 |
19.8 |
| 2.5 |
50 x 0.25 |
7.98 |
3.4 |
30.7 |
| 4 |
56 x 0.30 |
4.95 |
4.2 |
48.0 |
| 6 |
84 x 0.30 |
3.30 |
5.2 |
73.0 |
| 10 |
80 x 0.40 |
1.91 |
7.0 |
129 |
| 16 |
126 x 0.40 |
1.21 |
8.6 |
198 |
| 25 |
196 x 0.40 |
0.78 |
10.4 |
295 |
| 35 |
276 x 0.40 |
0.554 |
11.9 |
399 |
| 50 |
396 x 0.40 |
0.386 |
14.1 |
562 |
| 70 |
360 x 0.50 |
0.272 |
15.9 |
759 |
| 95 |
485 x 0.50 |
0.206 |
18.2 |
1024 |
| 120 |
608 x 0.50 |
0.161 |
20.3 |
1275 |
| 150 |
756 x 0.50 |
0.129 |
22.8 |
1587 |
| 185 |
944 x 0.50 |
0.106 |
24.8 |
1952 |
| 240 |
1221 x 0.50 |
0.0801 |
28.8 |
2560 |
| 300 |
1525 x 0.50 |
0.0641 |
31.5 |
3095 |
| 400 |
2037 x 0.50 |
0.0486 |
35.4 |
5130 |
Download:
Data Sheet
Silicoul 1.1 kV
GENERAL
Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
Good resistance to thermal shock and UV
Excellent ageing resistance
Good resistance to ozone and the corona effect
Excellent mechanical strength
Bending radius ≈ 5 x Diameter
Lloyds approved
Compatible with most impregnation varnishes
Working voltage: 1.1 kV. Test voltage: 3.5 kV. Max permissible current: consult our technical departments
COLOUR
All cross-sections: yellow
PACKAGING
100m Rolls, spools or drums
OPTIONS
UL/CSA approval: 1.1kV, style 3661
Without reinforcing braid
Other cross-sections: consult OBA
APPLICATIONS
Wiring of rotating machines: motors, alternators, generators
Wiring of static machines: transformers, inductors, inverters, choppers
Shipbuilding and railway construction
Power supply
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C (red copper core) |
Nominal outer diameter |
Approx. linear weight |
| [mm²] |
|
[Ω/km] |
[mm] |
[kg/km] |
| 1.5 |
30 x 0.25 |
13.7 |
3.8 |
29.0 |
| 2.5 |
50 x 0.25 |
8.21 |
4.3 |
37.8 |
| 4 |
56 x 0.30 |
5.09 |
4.9 |
58.5 |
| 6 |
84 x 0.30 |
3.39 |
6.0 |
76.6 |
| 10 |
80 x 0.40 |
1.95 |
7.0 |
121 |
| 16 |
126 x 0.40 |
1.24 |
8.6 |
178 |
| 25 |
196 x 0.40 |
0.795 |
10.4 |
273 |
| 35 |
276 x 0.40 |
0.565 |
11.9 |
376 |
| 50 |
396 x 0.40 |
0.393 |
14.1 |
534 |
| 70 |
360 x 0.50 |
0.277 |
15.9 |
738 |
| 95 |
485 x 0.50 |
0.210 |
18.2 |
970 |
| 120 |
608 x 0.50 |
0.164 |
20.3 |
1220 |
| 150 |
756 x 0.50 |
0.132 |
22.8 |
1520 |
| 185 |
944 x 0.50 |
0.108 |
24.8 |
1850 |
| 240 |
1221 x 0.50 |
0.0817 |
28.8 |
2420 |
| 300 |
1525 x 0.50 |
0.0654 |
31.5 |
3095 |
| 400 |
2037 x 0.50 |
0.0495 |
34.6 |
4130 |
Download:
Data Sheet
Silicoul 3.7 kV
GENERAL
Continuous working temperatures: -60°C to +180°C, Peaks at +230°C
Good resistance to thermal shock and UV
Excellent ageing resistance
Good resistance to ozone and the corona effect
Excellent mechanical strength
Bending radius ≈ 5 x Diameter
Lloyds approved
Compatible with most impregnation varnishes
Working voltage: 4.2 kV
COLOUR
All cross-sections: brown
PACKAGING
100m Rolls, spools or drums
OPTIONS
UL/CSA approval: 4.2 kV, style 3662
Without reinforcing braid
Other cross-sections: consult OBA
APPLICATIONS
Wiring of rotating machines: motors, alternators, generators
Wiring of static machines: transformers, inductors, inverters, choppers
Shipbuilding and railroad construction
Power supply
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C |
Nominal outer diameter |
Approx. linear weight |
| [mm²] |
|
[Ω/km] |
[mm] |
[kg/km] |
| 2.5 |
50 x 0.25 |
8.21 |
6.2 |
57.0 |
| 4 |
56 x 0.30 |
5.09 |
6.8 |
75.0 |
| 6 |
84 x 0.30 |
3.39 |
7.8 |
102 |
| 10 |
80 x 0.40 |
1.95 |
9.0 |
150 |
| 16 |
126 x 0.40 |
1.24 |
10.2 |
212 |
| 25 |
196 x 0.40 |
0.795 |
11.8 |
305 |
| 35 |
276 x 0.40 |
0.565 |
13.2 |
413 |
| 50 |
396 x 0.40 |
0.393 |
15.4 |
575 |
| 70 |
360 x 0.50 |
0.277 |
17.0 |
782 |
| 95 |
485 x 0.50 |
0.21 |
19.8 |
1030 |
| 120 |
608 x 0.50 |
0.164 |
21.8 |
1290 |
| 150 |
756 x 0.50 |
0.132 |
24.0 |
1580 |
| 185 |
944 x 0.50 |
0.108 |
25.4 |
1890 |
| 240 |
1221 x 0.50 |
0.0817 |
29.2 |
2451 |
| 300 |
1525 x 0.50 |
0.0654 |
31.8 |
3120 |
| 400 |
2037 x 0.50 |
0.0495 |
35.8 |
4160 |
Download:
Data Sheet
Silicoul 6.6 kV
GENERAL
Continuous working temperatures: -60°C to +180°C, Peaks at +230°C
Good resistance to thermal shock and UV
Excellent ageing resistance
Good resistance to ozone and the corona effect
Excellent mechanical strength
Bending radius ≈ 5 x Diameter
Lloyds approved
Compatible with most impregnation varnishes
Working voltage: 7.2 kV
Test voltage: 15 kV
Max. permissible current: consult OBA
COLOUR
All cross-sections: grey
PACKAGING
100m Rolls, spools or drums
OPTIONS
UL/CSA approval: 7.2 kV, style 3663
Without reinforcing braid
Other cross-sections: consult OBA
APPLICATIONS
Wiring of rotating machines: motors, alternators, generators
Wiring of static motors: transformers, inductors, inverters, choppers
Shipbuilding and railway construction
Power supply
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C (red copper core) |
Nominal outer diameter |
Approx. linear weight |
| [mm²] |
|
[Ω/km] |
[mm] |
[kg/km] |
| 4 |
56 x 0.30 |
5.09 |
8.2 |
95.0 |
| 6 |
84 x 0.30 |
3.39 |
9.1 |
120 |
| 10 |
80 x 0.40 |
1.95 |
10.3 |
172 |
| 16 |
126 x 0.40 |
1.24 |
11.5 |
238 |
| 25 |
196 x 0.40 |
0.795 |
13.0 |
330 |
| 35 |
276 x 0.40 |
0.565 |
14.6 |
440 |
| 50 |
396 x 0.40 |
0.393 |
16.7 |
612 |
| 70 |
360 x 0.50 |
0.277 |
18.3 |
825 |
| 95 |
485 x 0.50 |
0.210 |
20.5 |
1060 |
| 120 |
608 x 0.50 |
0.164 |
22.6 |
1315 |
| 150 |
756 x 0.50 |
0.132 |
24.9 |
1630 |
| 185 |
944 x 0.50 |
0.108 |
26.4 |
1935 |
| 240 |
1221 x 0.50 |
0.0817 |
30.2 |
2510 |
| 300 |
1525 x 0.50 |
0.0654 |
32.9 |
3180 |
| 400 |
2037 x 0.50 |
0.0495 |
37.0 |
4210 |
Download:
Data Sheet
Silicoul 13.8 kV
GENERAL
Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
Good resistance to thermal shock and UV
Excellent ageing resistance
Good resistance to ozone and the corona effect
Excellent mechanical strength
Bending radius ≈ 5 x Diameter
Lloyds approved
Compatible with most impregnation varnishes
Working voltage: 15 kV
Test voltage: 30 kV
Max. permissible current: consult OBA
COLOUR
All cross-sections: black
PACKAGING
100m Rolls, spools or drums
OPTIONS
UL/CSA approval: 15 kV, style 3664
Without reinforcing braid
Other cross-sections: consult OBA
APPLICATIONS
Wiring of rotating machines: motors, alternators, generators
Wiring of static machines: transformers, inductors, inverters, choppers
Shipbuilding and railway construction
Power supply
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C (red copper core) |
Nominal outer diameter |
Approx. linear weight |
| [mm²] |
|
[Ω/km] |
[mm] |
[kg/km] |
| 6 |
84 x 0.30 |
3.39 |
11.8 |
175 |
| 10 |
80 x 0.40 |
1.95 |
13.0 |
232 |
| 16 |
126 x 0.40 |
1.24 |
14.2 |
303 |
| 25 |
196 x 0.40 |
0.795 |
15.7 |
407 |
| 35 |
276 x 0.40 |
0.565 |
17.2 |
522 |
| 50 |
396 x 0.40 |
0.393 |
18.9 |
690 |
| 70 |
360 x 0.50 |
0.277 |
20.7 |
907 |
| 95 |
485 x 0.50 |
0.210 |
22.7 |
1160 |
| 120 |
608 x 0.50 |
0.164 |
24.7 |
1415 |
| 150 |
756 x 0.50 |
0.132 |
27.4 |
1758 |
| 185 |
944 x 0.50 |
0.108 |
28.9 |
2050 |
| 240 |
1221 x 0.50 |
0.0817 |
32.7 |
2660 |
| 300 |
1525 x 0.50 |
0.0654 |
35.3 |
3330 |
| 400 |
2037 x 0.50 |
0.0495 |
39.6 |
4360 |
Download:
Data Sheet
Varpren F
GENERAL
Working temperature: -50°C to +155°C,
Peak temperature: +170°C
Good compatibility with class F varnishes
Good resistance to atmospheric agents:
UV, Ozone, Oxygen
Excellent tearing resistance
Halogen free polyolefin elastomer
Bending radius ≈ 5 x Diameter
Nominal voltage: 600/1000 V
Test voltage: 2500 V
PACKAGING
100m Rolls, spools or drums
APPLICATIONS
Electrical motor applications
Rotating and static machines
Lighting
Power supplies, electrotechnical equipment
Shipbuilding and railways construction
| CORE |
ISOLATION / INSULATION |
| Cross-section |
Stranding |
Core resistance (20 °C) |
Wall thickness |
Outer diameter |
Weight |
| mm² |
|
Ω/km |
mm |
ø mm |
kg/km |
| 0.25 |
8 x 0.20 |
80.2 |
0.6 |
1.95 |
4 |
| 0.5 |
16 x 0.20 |
40.1 |
0.6 |
2.2 |
9 |
| 0.75 |
24 x 0.20 |
26.7 |
0.6 |
2.4 |
12 |
| 1 |
32 x 0.20 |
20 |
0.6 |
2.5 |
14 |
| 1.5 |
30 x 0.25 |
13.7 |
0.6 |
3 |
21 |
| 2.5 |
50 x 0.25 |
8.21 |
0.7 |
3.6 |
30.5 |
| 4 |
56 x 0.30 |
5.09 |
0.8 |
4.3 |
46.5 |
| 6 |
84 x 0.30 |
3.39 |
0.8 |
4.9 |
73 |
| 10 |
80 x 0.40 |
1.95 |
1 |
6.6 |
125 |
| 16 |
126 x 0.40 |
1.24 |
1 |
7.7 |
185 |
| 25 |
196 x 0.40 |
0.795 |
1.2 |
9.6 |
280 |
| 35 |
276 x 0.40 |
0.565 |
1.2 |
10.7 |
370 |
| 50 |
396 x 0.40 |
0.393 |
1.4 |
12.6 |
540 |
| 70 |
360 x 0.50 |
0.277 |
1.4 |
14.9 |
730 |
| 95 |
485 x 0.50 |
0.21 |
1.6 |
17.2 |
990 |
| 120 |
608 x 0.50 |
0.164 |
1.6 |
- |
1250 |
| 150 |
756 x 0.50 |
0.132 |
1.8 |
- |
1650 |
| 185 |
944 x 0.50 |
0.108 |
2 |
- |
1750 |
Download:
Data Sheet
Varpren MVA
GENERAL
Working temperature: -50°C to +150°C
Peak temperature: +170°C
Adequate resistance to thermal shocks
Good ageing in hot environments
Good resistance to atmospheric agents: UV, Ozone, Oxygen
Excellent tearing resistance
Halogen free cable
Fire retardant
Bending radius ≈ 10 x Diameter
Nominal voltage: 600/1000 V
Test voltage: 2500 V
PACKAGING
100m Rolls, spools or drums
APPLICATIONS
Electrical motor applications
Rotating and static machines
Lighting
Power supplies, electrotechnical equipment
Shipbuilding and railways construction
NB: MVA cables can be made to order
in 2 to 5 cores in sizes up to 2.5 mm2
| CORE |
INSULATION |
| Cross-section |
Stranding |
Core resistance (20 °C) |
Wall thickness |
Outer diameter |
| mm² |
|
Ω/km |
mm |
ø mm |
| 2 x 0.5 |
16 x 0.20 |
40.1 |
0.7 |
6.7 |
| 3 x 0.5 |
16 x 0.20 |
40.1 |
0.7 |
7.1 |
| 4 x 0.5 |
16 x 0.20 |
40.1 |
0.8 |
7.8 |
| 5 x 0.5 |
16 x 0.20 |
40.1 |
0.8 |
8.4 |
| 2 x 0.75 |
24 x 0.20 |
26.7 |
0.8 |
7.2 |
| 3 x 0.75 |
24 x 0.20 |
40.1 |
0.8 |
7.7 |
| 4 x 0.75 |
24 x 0.20 |
40.1 |
0.9 |
8.5 |
| 5 x 0.75 |
24 x 0.20 |
40.1 |
1 |
9.3 |
| 2 x 1 |
32 x 0.20 |
20 |
0.8 |
7.5 |
| 3 x 1 |
32 x 0.20 |
20 |
0.9 |
8.1 |
| 4 x 1 |
32 x 0.20 |
20 |
0.9 |
8.7 |
| 5 x 1 |
32 x 0.20 |
20 |
1 |
9.7 |
| 2 x 1.5 |
30 x 0.25 |
13.7 |
1 |
8.9 |
| 3 x 1.5 |
30 x 0.25 |
13.7 |
1 |
9.3 |
| 4 x 1.5 |
30 x 0.25 |
13.7 |
1 |
10.1 |
| 5 x 1.5 |
30 x 0.25 |
13.7 |
1 |
11 |
| 2 x 2.5 |
50 x 0.25 |
8.21 |
1 |
9.9 |
| 3 x 2.5 |
50 x 0.25 |
8.21 |
1 |
10.5 |
| 4 x 2.5 |
50 x 0.25 |
8.21 |
1 |
11.6 |
| 5 x 2.5 |
50 x 0.25 |
8.21 |
1 |
12.8 |
Download:
Data Sheet
NVS and NVSL
GENERAL
Continuous working temperatures: -60°C to + 350°C,
Peaks at + 400°C
Good resistance to thermal shock
Excellent ageing resistance
Good resistance to the usual chemical atmospheres
Working voltage: 300/500 V
Test voltage: 2000 V
COLOUR
Standard colour: brown.
All plain colours or with coloured spiral tracers on request, including green/yellow
PACKAGING
100m Rolls, spools or drums
OPTIONS
Please consult OBA about these options.
Teflon-coated (Teflon® PTFE varnish) fibreglass
braid
Multi-conductor assemblies - under silicone-coated fibreglass braid
- under galvanized steel shielding braid
Other cross-sections and flexibility classes: consult OBA
APPLICATIONS
Wiring of heating elements, cartridges, bands and hot plates
Domestic electrical heating appliances, professional kitchens and ovens
Machines for thermoplastics and rubber, etc
Furnaces and industrial ovens
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C (red copper core) |
Nominal outer diameter |
Approx. linear weight |
| [mm²] |
[??] |
[Ω/km] |
[mm] |
[kg/km] |
| SILICABLE® NVS |
|
|
| 0.25 |
4 x 0.30 |
351 |
1.9 |
6.50 |
| 0.5 |
7 x 0.30 |
178 |
2.1 |
8.70 |
| 0.75 |
11 x 0.30 |
114 |
2.4 |
11.9 |
| 1 |
14 x 0.30 |
91.0 |
2.5 |
14.5 |
| 1.5 |
21 x 0.30 |
61.0 |
2.8 |
20.5 |
| 2.5 |
35 x 0.30 |
36.5 |
3.2 |
32.2 |
| 4 |
56 x 0.30 |
23.8 |
4.3 |
50.1 |
| 6 |
84 x 0.30 |
15.1 |
4.8 |
72.3 |
| 10 |
140 x 0.30 |
8.7 |
6.8 |
131 |
| 16 |
228 x 0.30 |
5.8 |
8.2 |
206 |
| 25 |
354 x 0.30 |
3.6 |
10.1 |
323 |
| 35 |
495 x 0.30 |
2.6 |
12.0 |
423 |
| 50 |
707 x 0.30 |
1.9 |
13.2 |
591 |
| SILICABLE® NVSL (reduced outer diameters) |
|
|
| 0.22 |
7 x 0.20 |
395 |
1.2 ± 0.15 |
5.4 |
| 0.25 |
8 x 0.20 |
351 |
1.3 ± 0.15 |
6 |
| 0.34 |
11 x 0.20 |
257 |
1.4 ± 0.15 |
7.7 |
| 0.5 |
7 x 0.30 or 16 x 0.20 |
178 |
1.6 ± 0.15 |
8.5 |
| 0.6 |
9 x 0.30 or 19 x 0.20 |
140 |
1.7 ± 0.15 |
9.5 |
| 0.75 |
11 x 0.30 or 24 x 0.20 |
115 |
1.8 ± 0.20 |
11.5 |
| 1 |
14 x 0.30 or 32 x 0.20 |
91 |
2.1 ± 0.20 |
14 |
| 1.5 |
21 x 0.30 |
61 |
2.5 ± 0.20 |
20 |
| 2 |
28 x 0.30 |
46 |
2.9 ± 0.20 |
26 |
| 2.5 |
35 x 0.30 |
36.5 |
3.1 ± 0.25 |
31.7 |
| 4 |
56 x 0.30 |
23.8 |
3.6 ± 0.30 |
49 |
Download:
Data Sheet
BM-NVS
GENERAL
Continuous working temperatures: - 60°C to + 350°C,
Peaks at + 400°C
Good resistance to thermal shock
Excellent ageing resistance
Working voltage: 300/500 V
Test voltage: 2000 V
COLOUR
Colour-coding of insulated conductors (main products):3: Brown - Blue - Green/Yellow (earthing wire), 4: Black - Brown - Blue - Green/Yellow (earthing wire), 5: Black - Black - Brown - Blue - Green/Yellow(earthing wire)
Outer braid with or without coloured spiral tracers
PACKAGING
100m Rolls
OPTIONS
Please consult OBA about these options
Earthing wire in nickel-plated copper
All conductors in nickel-plated copper
Outer braid in stainless steel
Other cross-sections and conductor number: consult OBA
APPLICATIONS
Wiring of resistance, cartridges, hot-plates and heater bands
| INSULATED CONDUCTORS |
CABLE |
| Nominal cross-section |
Nominal stranding |
Approx. outer diameter |
Approx. outer diameter |
Approx. linear weight |
| mm² |
|
mm |
mm |
kg/km |
| 3 x 0.75 |
11 x 0.30 |
2.4 |
6.4 |
81.0 |
| 4 x 0.75 |
11 x 0.30 |
2.4 |
7.0 |
98.0 |
| 5 x 0.75 |
11 x 0.30 |
2.4 |
7.4 |
116 |
| 3 x 1 |
14 x 0.30 |
2.5 |
6.7 |
96.0 |
| 4 x 1 |
14 x 0.30 |
2.5 |
7.3 |
114 |
| 5 x 1 |
14 x 0.30 |
2.5 |
7.8 |
132 |
| 3 x 1.5 |
21 x 0.30 |
2.8 |
7.2 |
117 |
| 4 x 1.5 |
21 x 0.30 |
2.8 |
7.6 |
140 |
| 5 x 1.5 |
21 x 0.30 |
2.8 |
9.0 |
169 |
| 3 x 2.5 |
35 x 0.30 |
3.2 |
8.2 |
157 |
| 4 x 2.5 |
35 x 0.30 |
3.2 |
9.6 |
199 |
| 5 x 2.5 |
35 x 0.30 |
3.2 |
10.8 |
239 |
| 3 x 4 |
56 x 0.30 |
4.3 |
10.6 |
228 |
| 4 x 4 |
56 x 0.30 |
4.3 |
11.6 |
286 |
| 5 x 4 |
56 x 0.30 |
4.3 |
13.2 |
346 |
| 3 x 6 |
84 x 0.30 |
4.8 |
11.7 |
303 |
| 4 x 6 |
84 x 0.30 |
4.8 |
12.7 |
380 |
| 5 x 6 |
84 x 0.30 |
4.8 |
13.8 |
462 |
| 3 x 10 |
140 x 0.30 |
6.6 |
17.0 |
517 |
| 4 x 10 |
140 x 0.30 |
6.6 |
19.2 |
664 |
| 5 x 10 |
140 x 0.30 |
6.6 |
23.0 |
824 |
Download:
Data Sheet
NVAS
GENERAL
Continuous working temperatures: - 60°C to + 450°C, Peaks at + 550°C
Excellent resistance to thermal shock
Excellent ageing resistance
Good resistance to the usual chemical atmospheres
Lloyds approved
Working voltage: 300/500 V
Test voltage: 2000 V
COLOUR
Standard colour: grey
Any colour on request, including green/yellowers
PACKAGING
100m Rolls, spools or drums
OPTIONS
Please consult OBA about these options.
Multiconductor assemblies - under a braided mineral fibre sheath, - under a stainless steel shielding braid
Other cross-sections and flexibility classes: consult us
Very high temperature fibreglass insulating sheath: (outer diameters identical to type NVS)
APPLICATIONS
Wiring of heating elements, cartridges, bands and hot plates
Wiring of domestic electrical heating appliances, professional kitchens and ovens
Machines for thermoplastics and rubber, etc
Furnaces and industrial ovens
Heavy industry: foundries, steelworks, glassworks, etc
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C (nickel core) |
Nominal outer diameter |
Approx. linear weight |
| mm² |
|
Ω/km |
mm |
kg/km |
| 0.25 |
4 x 0.30 |
351 |
2.2 |
6.5 |
| 0.5 |
7 x 0.30 |
178 |
2.5 |
8.7 |
| 0.75 |
11 x 0.30 |
114 |
2.7 |
11.9 |
| 1 |
14 x 0.30 |
91 |
3.2 |
14.5 |
| 1.5 |
21 x 0.30 |
61 |
3.4 |
20.5 |
| 2.5 |
35 x 0.30 |
36.5 |
4 |
32.2 |
| 4 |
56 x 0.30 |
23.8 |
4.5 |
50.1 |
| 6 |
84 x 0.30 |
15.1 |
5.3 |
72.3 |
| 10 |
140 x 0.30 |
8.7 |
8 |
130 |
| 16 |
228 x 0.30 |
5.8 |
9 |
206 |
| 25 |
354 x 0.30 |
3.6 |
10.6 |
323 |
| 35 |
495 x 0.30 |
2.6 |
13.4 |
423 |
| 50 |
707 x 0.30 |
1.9 |
14 |
590 |
Download:
Data Sheet
TPT
GENERAL
Continuous working temperatures: + 125°C (Class B)
Excellent resistance to freon R12, R22, R134a, R502 and refrigerating fluids
Excellent resistance to alcohols and solvents
Working voltage: 600 V. Test voltage: 2500 V
COLOUR
Plain white or white with coloured spiral tracers
PACKAGING
100m Rolls, spools or drums
OPTIONS
Other cross-sections or flexibility classes: consult us
APPLICATIONS
Internal wiring of sealed motor units
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Max. linear resistance at 20°C |
Nominal outer diameter |
Approx. linear weight |
| mm² |
|
Ω/km |
mm |
kg/km |
| 0.75 |
42 x 0.15 |
26.0 |
1.8 |
8.80 |
| 1 |
32 x 0.20 |
19.5 |
1.9 |
11.2 |
| 1.5 |
30 x 0.25 |
13.3 |
2.3 |
16.8 |
| 2.5 |
50 x 0.25 |
7.98 |
2.8 |
29.2 |
| 4 |
56 x 0.30 |
4.95 |
3.2 |
43.8 |
| 6 |
84 x 0.30 |
3.30 |
3.8 |
65.0 |
| 10 |
80 x 0.40 |
1.91 |
6.5 |
116 |
| 16 |
126 x 0.40 |
1.21 |
7.5 |
181 |
| 25 |
196 x 0.40 |
0.78 |
8.8 |
280 |
| 35 |
276 x 0.40 |
0.55 |
10.1 |
385 |
| 50 |
396 x 0.40 |
0.39 |
11.6 |
550 |
Download:
Data Sheet
HT
GENERAL
Continuous working temperatures: - 60°C to + 180°C, Peaks at + 230°C
Good resistance to thermal shock, excellent resistance to ageing
Good resistance to humidity
Excellent resistance to ozone and the corona effect
Does not spread flame or fire
Pulsed voltage: from 5 to 50 kV
ECS-HT-VDE: working voltage 1.8/3 kV
COLOUR
Main products: refer to table
Colour of silicone insulator: brick red, white, black or translucent. Other colours: consult us
OPTIONS
Teflon insulated cables
Longitudinal marking on silicone insulator: consult OBA
Pure nickel or nickel-plated copper conductor: consult OBA
Other cross-sections and flexibility classes: consult OBA
Applications requiring design of a specific cable: consult OBA
PACKAGING
100m Rolls, spools, drums or SILIBOX®
APPLICATIONS
Ignition circuits, creation of electric arc
Piezo-electrics of domestic electrical appliances
Gas or fuel burners in boilers, and professional appliances
Neon electric signs
Burners in corrosive environments, near flames, molten glass or metal
|
CORE |
INSULATED WIRE |
|
Nominal c/section |
Nominal stranding |
Max. linear resistance at 20°C (tinned copper core) |
Thickness of silicone insulating sheath |
Nominal outer diameter |
|
mm² |
|
Ω/km |
mm |
mm |
| |
0.25 |
8 x 0.20 |
80.9 |
1.15 |
3 |
| 0.34 |
7 x 0.25 |
59.2 |
1.1 |
3 |
| 0.5 |
16 x 0.20 |
40.1 |
1 |
3 |
| (E)CS-HT |
1 |
32 x 0.20 |
20 |
2.45 |
6.2 |
| 1.5 |
30 x 0.25 |
13.7 |
3.2 |
8 |
| 2.5 |
50 x 0.25 |
8.21 |
3.45 |
9 |
| 4 |
56 x 0.30 |
5.09 |
3.7 |
10 |
| ECS-HT-VDE |
1 |
32 x 0.20 |
20 |
1.3 |
3.9 |
| 1.5 |
30 x 0.25 |
13.7 |
1.3 |
4.2 |
| (E)CSV-HT or (E)CSVRI-HT |
0.34 |
7 x 0.25 |
59.2 |
0.9 |
3 |
| 0.5 |
16 x 0.20 |
40.1 |
0.9 |
3.1 |
| (E)CSVCS-HT |
1.34 |
19 x 0.30 |
15 |
2.75 |
7 |
| 1.5 |
30 x 0.25 |
13.7 |
2.85 |
7.3 |
| CSABI-HT |
1.5 |
30 x 0.25 |
13.7 |
3.2 |
10 |
|
2.5 |
50 x 0.25 |
8.21 |
3.5 |
11 |
|
4 |
56 x 0.30 |
5.09 |
3.7 |
12 |
Download:
Data Sheet
EETFE
GENERAL
Continuous working temperatures: -90°C to +155°C, Peaks at +180°C
Excellent resistance to aggressive chemical atmospheres
Excellent resistance to humidity and UV
Excellent mechanical strength
Working voltage: 450/750 V
Test voltage: 2500 V
COLOUR
All colours, including translucent
OPTIONS
Please consult OBA about these options.
Nickel-plated copper core
Silver-plated copper core
Pure nickel core
Cross-sections up to 240 mm²: consult OBA
Other flexibility classes: consult OBA
PACKAGING
100m Rolls, spools, drums or SILIBOX®
APPLICATIONS
Wiring of rotating machines, class F
Wiring in household appliances, electronics
Wiring in hot or cold environments (cryogenics)
Wiring in aggressive atmospheres (humid, chemical, etc.)
Wiring that requires compact fitting and excellent mechanical strength
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Nominal diameter |
Max. linear resistance at 20 °C (red copper wire) |
Nominal insulation thickness |
Outer diameter
mm |
Approx.
linear weight |
| mm² |
|
mm |
Ω/km |
mm |
|
kg/km |
| 0.05 |
7 x 0.10 |
0.30 |
373 |
0.17 |
0.65 |
0.90 |
| 0.12 |
7 x 0.15 |
0.45 |
161 |
0.17 |
0.80 |
1.70 |
| 0.15 |
19 x 0.10 |
0.50 |
136 |
0.2 |
0.90 |
2.10 |
| 0.22 |
7 x 0.20 |
0.60 |
89.9 |
0.2 |
1.00 |
2.80 |
| 0.25 |
19 x 0.13 |
0.65 |
79.9 |
0.2 |
1.05 |
3.20 |
| 0.34 |
7 x 0.25 |
0.75 |
58.9 |
0.2 |
1.15 |
4.10 |
| 0.34 |
19 x 0.15 |
0.75 |
58.9 |
0.2 |
1.15 |
4.10 |
| 0.5 |
7 x 0.30 |
0.90 |
39.6 |
0.2 |
1.30 |
5.70 |
| 0.5 |
16 x 0.20 |
0.90 |
39.0 |
0.2 |
1.30 |
5.70 |
| 0.6 |
19 x 0.20 |
1.00 |
32.8 |
0.2 |
1.40 |
6.70 |
| 0.75 |
24 x 0.20 |
1.05 |
26.0 |
0.2 |
1.45 |
7.82 |
| 0.93 |
19 x 0.25 |
1.25 |
21.0 |
0.25 |
1.70 |
10.2 |
| 1 |
32 x 0.20 |
1.20 |
19.5 |
0.25 |
1.70 |
10.6 |
| 1.34 |
19 x 0.30 |
1.40 |
14.6 |
0.25 |
1.90 |
13.9 |
| 1.5 |
30 x 0.25 |
1.45 |
13.3 |
0.3 |
1.95 |
15.2 |
| 2.5 |
50 x 0.25 |
1.90 |
7.98 |
0.3 |
2.50 |
25.6 |
| 4 |
56 x 0.30 |
2.55 |
4.95 |
0.3 |
3.30 |
41.4 |
| 6 |
84 x 0.30 |
3.10 |
3.30 |
0.35 |
3.90 |
61.7 |
| 10 |
80 x 0.40 |
4.40 |
1.91 |
0.4 |
5.20 |
100 |
| 16 |
126 x 0.40 |
5.40 |
1.21 |
0.4 |
6.20 |
157 |
Download:
Data Sheet
EPFA
GENERAL
Continuous working temperatures: -90°C to +260°C, Peaks at +280°C
Excellent resistance to aggressive chemical atmospheres
Excellent resistance to humidity and UV
Excellent mechanical strength
Working voltage: 450/750 V
Test voltage: 2500 V
COLOUR
All colours, including translucent
OPTIONS
Please consult OBA about these options.
Nickel-plated copper core
Silver-plated copper core
Pure nickel core
MFA fluorinated polymer insulator (- 90°C to + 240°C)
Cross-sections up to 240 mm²: consult OBA
Other flexibility classes: consult OBA
PACKAGING
100m Rolls, spools, drums or SILIBOX®
APPLICATIONS
Wiring in household appliances, electronics
Wiring in hot and cold environments (cryogenics)
Wiring in aggressive environments (humid, chemical, etc.)
Wiring that requires compact fitting and excellent mechanical strength
| CORE |
INSULATED WIRE OR CABLE |
| Nominal cross-section |
Nominal stranding |
Nominal diameter |
Max. linear resistance at 20 °C (red copper wire) |
Nominal insulation thickness |
Outer diameter |
Approx.
linear weight |
| mm² |
|
mm |
Ω/km |
mm |
mm |
kg/km |
| 0.05 |
7 x 0.10 |
0.30 |
373 |
0.17 |
0.65 |
1.0 |
| 0.12 |
7 x 0.15 |
0.45 |
161 |
0.17 |
0.80 |
1.8 |
| 0.15 |
19 x 0.10 |
0.50 |
136 |
0.20 |
0.90 |
2.3 |
| 0.22 |
7 x 0.20 |
0.60 |
89.9 |
0.20 |
1.00 |
3.0 |
| 0.25 |
19 x 0.13 |
0.65 |
79.9 |
0.20 |
1.05 |
3.4 |
| 0.34 |
7 x 0.25 |
0.75 |
58.9 |
0.20 |
1.15 |
4.3 |
| 0.34 |
19 x 0.15 |
0.75 |
58.9 |
0.20 |
1.15 |
4.3 |
| 0.5 |
7 x 0.30 |
0.90 |
39.6 |
0.20 |
1.30 |
6.0 |
| 0.5 |
16 x 0.20 |
0.90 |
39.0 |
0.20 |
1.30 |
6.0 |
| 0.6 |
19 x 0.20 |
1.00 |
32.8 |
0.20 |
1.40 |
7.0 |
| 0.75 |
24 x 0.20 |
1.05 |
26.0 |
0.20 |
1.45 |
8.0 |
| 0.93 |
19 x 0.25 |
1.25 |
21.0 |
0.25 |
1.70 |
10.6 |
| 1 |
32 x 0.20 |
1.20 |
19.5 |
0.25 |
1.70 |
11.0 |
| 1.34 |
19 x 0.30 |
1.40 |
14.6 |
0.25 |
1.90 |
14.3 |
| 1.5 |
30 x 0.25 |
1.45 |
13.3 |
0.30 |
1.95 |
15.6 |
| 2.5 |
50 x 0.25 |
1.90 |
7.98 |
0.30 |
2.50 |
26.3 |
| 4 |
56 x 0.30 |
2.55 |
4.95 |
0.30 |
3.30 |
42.3 |
| 6 |
84 x 0.30 |
3.10 |
3.30 |
0.35 |
3.90 |
63.5 |
| 10 |
80 x 0.40 |
4.40 |
1.91 |
0.40 |
5.20 |
103.0 |
| 16 |
126 x 0.40 |
5.40 |
1.21 |
0.40 |
6.20 |
159.0 |
Download:
Data Sheet
Thermocouple cables (COUPLIX)
GENERAL
Thermoelectric effect (Seebeck): The thermoelectric effect consists of the production of an electromotive force (emf) created by the temperature difference between two different metal or alloy junctions making up the same circuit.
Thermocouple: A thermoelectric couple is formed by a pair of conductors of different types connected at their ends, to provide a complete circuit that can be used for measuring temperature by thermoelectric effect.
Extension Cables: Extension cables are manufactured with wires of the same composition as the wires of the corresponding couples. They are coded with the letter "X" placed after the thermocouple code, for example "JX".
Compensation Cables: Compensation cables are manufactured with wires of different stranding or material to the wires of the corresponding thermocouples. They are marked by the letter "C" placed after the thermocouple code, for example "KC". Different alloys can be used for the same type of thermocouple.
Note: All stocked thermocouple cables are supplied in A.N.S.I. colour code.
COLOUR
All colours, including translucent
OPTIONS
Other cross-sections and stranding: consult OBA
Other insulation: consult OBA
Multipair cables, with or without individual screen with or without general screen: consult OBA
Imposed maximum outer diameters: consult OBA
Hybrid cables: consult OBA
APPLICATIONS
Anywhere to measure heat
|
|
|
Insulation |
|
|
|
No. of Pairs |
Nominal Cross Section |
Conductor |
Sheath |
Continuous working temperature of insulation |
Sheath Colour |
|
|
[mm²] |
|
|
|
|
| Type J Single Pair |
| J-BIMV-VS |
1 |
0.22 |
Fibreglass |
Fibreglass/Stainless Steel Braid |
-60ºC to + 400ºC |
Stainless Steel |
| J-M5-5 |
1 |
0.22 |
PFA |
PFA |
-190ºC to +260ºC |
Brown |
| J-MV-VS |
1 |
0.22 |
Fibreglass |
Fibreglass |
-60ºC to +400ºC |
Brown |
| Type J Single Pair Extension |
| JX1-MY2-Y2 |
1 |
0.22 |
PVC 105C |
PVC 105C |
-30ºC to +105ºC |
Black |
| Type K Single Pair |
| K-BIM5-5 |
1 |
0.22 |
PFA |
PFA/Stainless Steel Braid |
-60ºC to +260ºC |
Stainless Steel |
| K-BIMV-VS |
1 |
0.22 |
Fibreglass |
Fibreglass/ Stainless Steel Braid |
-60ºC to +400ºC |
Stainless Steel |
| K-M5-5 |
1 |
0.22 |
PFA |
PFA |
-190ºC to +260ºC |
Brown |
| K-MV-VS |
1 |
0.22 |
Fibreglass |
Fibreglass |
-60ºC to +400ºC |
Brown |
| Type K Single Pair Extension |
|
|
|
|
|
|
| KX1-MY2-Y2 |
1 |
0.22 |
PVC 105C |
PVC 105C |
-30ºC to +105ºC |
Yellow |
| Type T Single Pair |
|
|
|
|
|
|
| T-M5-5 |
1 |
0.22 |
PFA |
PFA |
-190ºC to +260ºC |
Brown |
| Type K Multi Pair Extension (Overall screened plus drain wire) |
| KX1-MY2BAL-M-Y2 |
1 |
0.22 |
PVC 105C |
PVC 105C |
-30C to +105C |
Yellow |
| KX1-MY2BAL-M-Y2 |
4 |
0.22 |
PVC 105C |
PVC 105C |
-30C to +105C |
Yellow |
| KX1-MY2BAL-M-Y2 |
6 |
0.22 |
PVC 105C |
PVC 105C |
-30C to +105C |
Yellow |
| KX1-MY2BAL-M-Y2 |
8 |
0.22 |
PVC 105C |
PVC 105C |
-30C to +105C |
Yellow |
| KX1-MY2BAL-M-Y2 |
12 |
0.22 |
PVC 105C |
PVC 105C |
-30C to +105C |
Yellow |
| KX1-MY2BAL-M-Y2 |
24 |
0.22 |
PVC 105C |
PVC 105C |
-30C to +105C |
Yellow |
Download:
Data Sheet
RTD Cables (SONDIX)
GENERAL
The electrical resistance of a metal conductor increases with temperature
This variation is reversible
Platinum is the metal most often used
COLOUR
Cables with 2, 3 or 4 conductors
Other number of conductors on request
Colour-coding:
2 conductors: red/white
3 conductors: red/red/white
4 conductors: red/red/white/white
Standard colour of silicone sheaths: grey
Standard colour of FEP or PFA sheaths: white
Standard colour of outer fibreglass sheaths: white
Other colours on request
Types of core: red, tinned, silver-plated or nickel-plated copper
Outer diameters: consult OBA
OPTIONS
Other number of conductors: consult OBA
Other cross-sections and conductor metals: consult OBA
High-performance insulation, for temperatures up to 850°C and above: consult OBA
Parallel assembly, flat cables: consult OBA
APPLICATIONS
Cabling for platinum resistance temperature detectors
PACKAGING
Other types and conductor configurations can be made to order These cables are available in other pack sizes in multiples of 100m
|
|
|
Insulation |
|
|
|
|
Nominal
Cross
Section
[mm²] |
No. of Cores |
Insulation
Type |
Insulation
Conductor |
Sheath |
Continuous
working
temperature
of insulation |
Sheath
Colour |
Pack
Size |
| 0.22 |
3 |
M5BAL-E5 |
PFA |
PFA |
-190°C to +260°C |
White |
500m |
| 0.22 |
4 |
M5BAL-E5 |
PFA |
PFA |
-190°C to +260°C |
White |
500m |
| 0.22 |
6 |
M5BAL-E5 |
PFA |
PFA |
-190°C to +260°C |
White |
500m |
Download:
Data Sheet
|
|
|
 |